Antimicrobial Dressings

Mepilex Border Sacrum Ag

Self-adherent antimicrobial soft silicone foam dressing

Product: REF {{ store.currentProductVariant?.productId }}
  • {{ feature }}
  • Certified by ISCC
  • FSC certified paper
  1. How the product works

  2. Mepilex Border Sacrum Ag consists of a Safetac® soft silicone wound contact layer, an absorbent polyurethane foam pad containing silver sulphate and coloured by activated carbon, a layer with super absorbent fibres, a nonwoven and a breathable and water proof film. Safetac® is a proprietary adhesive technology developed by Mölnlycke that minimises pain to patients and trauma to intact skin or wounds. Mepilex Border Sacrum Ag is a soft silicone foam dressing that absorbs exudate, maintains a moist wound healing environment and has antimicrobial properties. Mepilex Border Ag contains silver sulphate to create an effective bacterial barrier and inactivate a wide range of wound related pathogens (bacteria and fungi), as shown in vitro. By reducing the number of microorganisms, Mepilex Border Ag may also reduce odour. Mepilex Border Sacrum Ag has been shown to inactivate wound related pathogens up to 7 days in vitro.

    1. 01
    2. 02
    1. Mölnlycke Health Care. Data on File.
    2. Huss, F., Thorfinn, J. An open, non-controlled, postmarketing investigation evaluating the experience of using a self-adherent antimicrobial soft silicone, silver containing, foam dressing, Mepilex Border Ag, in second degree burns. PMCF study MxB Ag 02 from Mölnlycke Health Care. Unpublished data, 2011. Latenser, B., Alvarez, OM., Treadwell, T. Open multicentre investigation to evaluate signs and symptoms of local inflammation/infection on chronic ulcers and partial thickness burns when using Mepilex Border Ag as an anti-microbial wound dressing. PMCF study MxB Ag 01 from Mölnlycke Health Care. Unpublished data, 2012. Kles C.L., Murrah, C.P., Smith, K., Baugus- Wellmeier, E., Hurry, T., Morris, C.D. Achieving and sustaining zero. Preventing surgical site infections after isolated coronary artery bypass with saphenous vein harvest through implementation of a staffdriven quality improvement process. Dimensions of Critical Care Nursing 2015;34(5):265-272.
  3. Ref: {{ orderingInformationRow.variantId }}

    Packaging level Quantity GTIN code
    {{ row.packagingLevel }} {{ row.quantity }} {{ row.gtinCode }}

    Manufacturer: {{ orderingInformationRow.manufacturer }}

    {{ info.key }}: {{ info.value }}

接触

Mölnlycke製品の詳細と使用法に関する質問

マーケットを選択

知識を得る、製品について学ぶ、サポートを依頼する

Japanese (Japan)

No markets

求人情報、財務報告書 等を見る

Mölnlycke コーポレート

あなたは医療従事者ですか?

このウェブページには、医療従事者のみを対象とした情報が含まれています。「はい、はい」を選択することで、あなたが医療従事者であることを確認したことになります。